WATER BATH SEROLOGICAL
WATER BATH SEROLOGICAL-STI-134
WATER BATH SEROLOGICAL

PRODUCT APPRAISAL/APPLICATION

Serological water/Liquid bath is widely used for bacteriological and varied laboratory applications requiring general tests and procedures in variety of research and testing laboratories. Apart from that Serological Water Bath is conceptualized & designed to handle Clinical procedures, Incubation as well as most Serological, Pharmaceutical, Biomedical procedures and various other general and specialized applications in laboratories.

BASIC CONSTRUCTION

Serological Water/Liquid Bath is a sturdy, robust double walled heating unit. Complete Inner/Working Chamber is made of High Grade satin finish thick STAINLESS STEEL sheet. Outer Chamber is fabricated out of thick Mild Steel Sheet duly pre treated with primers for rust proofing & attractively finished with durable powder coated paint. The Gap in between the walls is filled with high grade Super Glass Wool Insulation to prevent any thermal losses. Water Bath is provided with a pyramidal shaped top cover and perforated removable diffuser tray to cover immersion heaters but supplied  without rack or thermometer. 

PYRAMIDAL LID

Unit is Incorporated with a pyramidal lid shaped top cover so as to prevent falling of the condensed water droplets on to the specimen.

DRAIN

 Water Bath is provided with a Drain Plug to facilitate easy empting and cleaning of the Inner Chamber whenever required.

TEMPERATURE (Heating Elements)

To impart uniform heating throughout the chamber, High Grade Immersion Heating Element is fitted at the bottom of the Serological Water Bath with different rating for different sizes and is covered with perforated removable diffuser tray made of Stainless Steel Sheet.

TEMPERATURE RANGE (CONTROL & SENSTIVITY)

Temperature Range of the serological Bath is 50C above ambient to 950C& is maintained by Quality Hydraulic Thermostat with a sensitivity of + 10C/+ 20C or as shown in the thermometer. Optionally models Incorporated with Digital Temperature Controller Cum Indicator/Microprocessor PID controllers have an accuracy of + 0.2/0.50C

FRONT CONTROL PANEL

Front control panel consists of Indicator Lamps for Heating and Mains, On/Off Switch, Thermostatic controller/ Digital Controller or PID Controller (Optional).

POWER REQUIREMENTS

Suitable to operate on 220 Volts, 1 phase, 50 Hz, AC supply.

TECHNICAL FEATURES & SECIFICATIONS

 

TEMPERATURE

RANGE

50C above ambient to 950C

TEMPERATURE SENSITIVITY

+  1/20C

(Optionally models Incorporated with Digital Temperature Controller Cum Indicator/Microprocessor PID controllers have an accuracy of + 10C /0.50C)

TEMPERATURE

SENSOR

Capillary Thermostat/ Pt-100 Sensor(Optional)

TEMPERATURE CONTROLLER

Thermostatically Controlled (Capillary Type)

(Optional) Solid State Digital Temperature Controller Cum Indicator/Micro-processor based PID Controller 

INNER CHAMBER

Corrosion resistant satin finish Stainless Steel Interior

 

INNER CHAMBER DIMENSIONS   

 

           (L x W x D)

 

     RACKS

 

RATING (KW)

 

Volume (Litres)

 

· 300 x 250 x 175 mm

 

       2 Racks

 

       1.0

 

                13.0

 

· 325 x 300 x 175 mm

      

       4 Racks

      

       1.0         

 

                17.0   

 

· 450 x 300 x 175 mm

 

       6 Racks

 

       1.5

 

                  23.0

 

 

· 600 x 300 x 175 mm

 

       8 Racks

 

       1.5

 

                  31.0

UPGRADES

(OPTIONAL ACCESSORIES)

 

  • Stirring Arrangement with the help of FHP motor complete with S.S. Stirring Rod & Speed Regulator
  • Solid State Digital Temperature Controller Cum Indicator in lieu of Thermostat & Thermometer
  • Microprocessor based PID Temperature Controller Cum Indicator (Dual Display)

ADVANCED OPTIONALS

  • Semi auto Process Control Unit. This is an advanced feature comprising of Microprocessor based PID Temperature controller cum Indicator with In Built Digital Timer with Buzzer (Optional). Temperature is     controlled by Dual Display PID Controller exhibiting PV (Process Value) and SV (Set Value). Once the Set Value is achieved the Digital Timer starts functioning & the equipment now functions for the process/time Set by the user or as required by the user & on completion of the process switches ‘off’ the heaters automatically & gives a Buzzer sound indicating that the process is complete.
  • Port for Computer Interface.
  • Data Logger for Data Acquisition to log in temperature related details pertaining to Water Bath by means of RS 232 interface.

 

Note: 

  • Above mentioned sizes are of standard water bath series. However, we are capable to manufacture/fabricate any customized size as per customer’s exact requirement.
  • Following company’s constant endeavor to improve design & quality, the   instrument may differ in detail, description or as exhibited in this manual.