EXHIBITION & AWARDS  |  PRODUCTS CATALOGUE  


An ISO 9001:2008 Certified Company
Send Online Enquiry
BIOLOGICAL SAFETY CABINET TOTAL CONTAINMENT CABINET  CLASS III
BIOLOGICAL SAFETY CABINET TOTAL CONTAINMENT CABINET CLASS III-STI-229 B
BIOLOGICAL SAFETY CABINET TOTAL CONTAINMENT CABINET  CLASS III

 

BIOLOGICAL SAFETY CABINET (TOTAL CONTAINMENT CABINET)  CLASS III  "With Material Transfer through Interchange Box" 

PRODUCT APPRAISAL/APLLICATION

The class III Bio safety cabinet is the most versatile unit for Micro Biological manipulations. Class III bio-safety cabinet provides Personnel & Environmental Protection. Biological Safety Cabinet as the name suggests is conceptualized & designed for applications which include isolation and identification of Plant/Human pathogens, work in Virology, Tissue culture, sterility testing and recombinant DNA research.

 

CLASS III BIOSAFE PROCESS & AIR FLOW PATTERN                     (100% EXHAUST MODE)

Class III Bio Safety Cabinets are totally enclosed ventilated units. When in use, these Cabinets maintain negative air pressure through out. Incorporated with air tight enclosure with a non-opening completely sealed viewing window. These cabinets are designed for use with high risk biological agents. Class III cabinet provides the highest level of personnel, product & environmental protection. Access to the work area is through Glove ports only & also the loading of the samples is done through a double door interchange pass box which also facilitates safe removal of samples. Negative pressure air surrounds all biological contaminated parts. Both supply and exhaust air is HEPA filtered. With no recirculation mode, air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) & the same is exhausted also through HEPA. If the air needs to be exhausted to outdoors, another out connected duct need to be ordered, and an extra duct and motor blower (option) are required.The operations within the Class III cabinets are conducted through attached Rubber Gloves incorporated at the front. Supply air is drawn into the cabinet through HEPA filter. The cabinet exhaust air is filtered by an additional HEPA filter before discharge outside the facility. 

CLASSIFICATION/ CLEANLINESS LEVEL

Bio Safety Cabinets are designed to meet the requirements of United States Federal standard 209 providing particle free air to meet the class 100 requirements. Most useful for microbiological manipulations

 

FILTER ASSEMBLY

  • PRE FILTER: Laminar air flow is fitted with washable synthetic pre-filter units
  • MAIN FILTER/HEPA FILTER: At the Delivery end, the unit is incorporated with High Efficiency Particulate Filters (HEPA) made of mini pleated non-woven fabric.
  • FILTER DESCRIPTION: Laminar air flows are fitted with washable synthetic pre-filter units and secondary high efficiency perfect air filters made of pleated Non Woven Fabric. The efficiency of the filters has a rating better than 99.99% at DOP (cold) and 99.97% at DOP (Hot). These units have the capacity to hold all suspended particles of size 0.3 microns or larger. At the delivery end, the unit is provided with HEPA Filters (High Efficiency Particulate Air Filter) comprising of Non-Woven Micro fiber Glass pleated media. The pleats are separated by corrugated Aluminium foil separators. The filter has Rubber padding for a perfect rubber to rubber sealing. Air drawn through Pre filter is made to pass through highly effective High Efficiency Particulate filter having efficiency rating as high as 99.99% with cold DOP & 99.97% with hot DOP, thus retaining all Air borne particles of size 0.3microns and larger.

 

MOTOR & DYNAMICALLY BALANCED BLOWER ASSEMBLY

Incorporated with a heavy duty efficient motor which operates with minimum noise levels. Using a Dynamic Machine, the Motor & Blower Assembly is both statically and dynamically balanced ensuring minimum vibration and noise levels.

 
POWER REQUIREMENTS
Suitable to operate on 220/230 Volts, Single phase, 50 Hertz, AC supply.

 

TECHNICAL FEATURES & SPECIFICATIONS

 

INNER WORKING

DIMENSIONS

    2’  x  2’  x  2’

(600 x 600 x 600 mm)

   3’  x  2’  x  2’

 (900 x 600 x 600 mm)

   4’  x  2’  x  2’

 (1200 x 600 x 600 mm)

   6’  x  2’  x  2’ 

(1800 x 600 x 600 mm)

   8’  x  2’  x  2’

(2400 x 600 x 600 mm)

HEPA FILTER

(SIZE)

  2’  x  2’  x  6”

    3’  x  2’  x  6”

4’  x  2’  x  6”

      3’  x  2’  x  6”

    4’  x  2’  x  6”

HEPA FILTER (No.)

          1

              1              

      1              

            2   

             2  

PRE FILTER

  WASHABLE SYNTHETIC PRE FILTERS

HEPA FILTER

  • Glass Pleated Non Woven Fabric separated by corrugated Aluminium foil separators
  • Efficiency rating as high as 99.99% with cold DOP & 99.97% with hot DOP
  • Retaining all Air borne particles of size 0.3microns and larger

AIR FLOW PATTERN

  Unidirectional

EXHAUST

  Complete Air Exhaust through HEPA Filter

GLOVE PORTS

  Quality Rubber Gloves for absolute safety

ILLUMINATION

  Diffused Glare free fluorescent light

POWER REQUIREMENT

  220/230 Volts, 50 Hertz, AC supply

CABINET CONSTRUCION

  COMMERCIAL GRADE WOODEN BOARD

  MILD STEEL SHEET/G.I SHEET

 STAINLESS STEEL SHEET

 UPGRADES 

(Optional Accessories)

  • ULPA Filters instead of HEPA Filters
  • Microprocessor Based Controller (LCD Display – Feather Touch Controls)
  • Gas/air/vacuum line cock
  • Timer for UV Tube

 

 

Note: Following Company’s constant endeavor to improve design &Quality the equipment may differ in detail, description or as shown in this catalogue.

 

Testimonials


“ ”
Om Sai Ram
Socialize With Us :