MODE OF HEATING
-
Electrically heated by special flange type/Immersion type Heating Elements bearing ISI Mark/Equaivalent Quality Mark
-
Suitable to operate on 440 Volts, Three phase, AC supply
-
Incorporated with Quality Heavy Duty Contactor of L&T/Equivalent Quality make
WORKING PRESSURE/WORKING TEMPERATURE
-
Pressure Range: Pressure inside the chamber is variable from 5 psi to 20 psi
-
The normal recommended pressure for sterilization process is 1.2 Kg/cm2 (15psi-17 psi)
-
Working Pressure:15 psi+ 1/2 psi, Working Temperature:1210C approximately
SALIENT FEATURES
-
Three Way Valve/Multiple operating Valve: Facilitates functions of sterilization cycle at one point i.e from Boiler to Steam Jacket, Jacket to chamber & Chamber to release position or exhaust
-
Stainless Steel Heavy Gauge Steam Generator (Boiler) Incorporated underneath the chamber & is fitted with:
1. ISI Marked/Equivalent Quality Immersion type Heating Elements
2. Automatic Pressure control Switch
3. Auto Low Water Level Cut off Device
4. Water Inlet & Outlet Valves
5. Water Level indicating glass gauge &Pressure gauge
-
Double Door/Lid: Heavy duty Stainless Steel Lid with Double Safety Radial Locking system of MS duly chrome
-
Gasket: Incorporated with Moulded joint less Neoprene Rubber Gasket/Silicon Rubber Gasket(optional)
-
Vacuum Breaker: Safety device to prevent vacuum formation in the chamber & to remove residual air
-
Moisture/Steam Trap/Chamber Condensate: Incorporated with a steam trap and check valve for perfect condensation from chamber to achieve optimum temperature
-
Spring Loaded Safety Valve
-
Pressure & Compound Gauge
-
Electrical Control Box: Equipped with Industrial Grade Quality Contractor, Microprocessor based Digital Autoclave Controller, toggle switch/ MCB & neon Indicating lamps.
ADVANCED FEATURES:
-
Microprocessor based Digital Autoclave Controller with Alpha Numeric Display (Feather touch controls)
-
Digital Display of Temperature & Timer
-
Temperature Settable
-
Sterilizing Cycle time settable
-
AUTOMATIC PURGING OF STALE AIR: The Air Valve remains opens up to 1000C for priming. As soon as the unit achieves temperature of 1000C, the Solenoid Valve gets closed & starts generating pressure in the chamber.
-
AUTO EXHAUST OF STEAM: As soon as the cycle is over, the Steam is released automatically through Solenoid valve.
TECHNICAL SPECIFICATIONS
MODEL |
STI-118 D 40 L |
STI-118 D 88 L |
STI-118 D 150 L |
STI-118 D 165L |
STI-118 D 221 L |
Inner Dimensions: (Dia x Height) |
300 x 500 mm |
400 x 600 mm |
400 x 1100 mm |
500 x 900 mm |
500 x 1200 mm |
Capacity (In Litres) |
40 Litres |
88 Litres |
150 Litres |
165 Litres |
221 Litres |
Rating/Load (KW) (Approx) |
5.0 KW |
6.0 KW |
9.0 KW |
9.0 KW |
9.0 KW |
Sterilizing Pressure |
1.2 Kg/cm2 (15 psi-17 psi) |
Power Supply |
440 Volts, Three phase, AC supply |
Optional Accessories:
-
Dot Matrix Printer Port
-
RS- 485 Port for printer & software
-
Self locking Door closing Device
-
Gauge Calibration Certificate
-
Digital Controller Calibration Certificate
-
Pressure sensor Input
-
GMP (Complete Stainless Steel)
Note:
-
Above mentioned sizes are of standard Autoclave series. However, we are capable to manufacture/fabricate any special size as per customer’s exact requirement.
-
Following company’s constant endeavor to improve design & quality, the instrument may differ in detail, description or as exhibited in this manual.